Description
An installation of 44 P4 helical piles underneath a concrete foundation to support a tower crane. This crane will be used in the construction phase of three multi-family buildings.
Year
2025
Contracted Dealership
Techno Pieux Québec Est
Client
Construction Dinamo
Location Address
77 route du Président-Kennedy in Lévis, Qc
Engineering Firm
Iconex
General Contractor
Construction Dinamo
Project Goals
Install piles to support a concrete block foundation measuring 7.8 m x 7.8 m x 1.9 m thick. This concrete foundation is being used to support a crane for the construction of three (3) multi-story residential towers (18 to 24 stories). The piles were required as a foundation support due to the low bearing capacity of the surrounding soil and the heavy loads being transferred by the crane and the concrete block.
Specific challenges
- Tight deadline
- Accessibility
- Limited workspace.
Our advantages compared to other installation methods
- Quick installation
- Efficient and timely coordination between the design engineer, the dealer and Techno Metal Posts' engineering department.
Soil type
Backfill, clay, and sand with low bearing capacity
Number of people on site
2 (1 installer + 1 welder)
Piles used
Model P4
Equipment used
Load to be supported by pile (bearing capacity)
Service load between 205 kN (compression) and 35 kN (tension)
Torque per pile
± 14,700 lb-ft
Engineer's guidelines
Position certain piles at a slight angle (± 5 degrees) to ensure optimal pile layout and load transfer in both compression and tension.
Depth of embedment
± 5.3 m from the bottom of the excavation. The piles rest on the bedrock (shale).
Details of the structure resting on the piles
Concrete block measuring 7.8 m x 7.8 m x 1.9 m thick.